AI paper index

PLCBench: Can Autonomous LLM Agents Turn PLC Access into Sustained Physical Impact?

2026-08-27 · arXiv: 2608.26882

One-line summary

An AI research paper on PLCBench: Can Autonomous LLM Agents Turn PLC Access into Sustained Physical Impact?.

Engineering notes

Engineering notes will be added by the aipentium editorial team.

Chinese explanation / 中文解读

中文解读待补充:本站会优先为大语言模型、生成式AI、ChatGPT相关技术、计算机视觉、深度学习等高价值论文补充中文说明。

Original abstract

Industrial control systems (ICSs) rely on programmable logic controllers (PLCs) to connect networked computation with physical control. Tool-using large language model (LLM) agents represent an emerging attack threat: can an autonomous agent convert a network-reachable PLC into sustained adverse physical impact? However, existing evaluations focus on digital tasks or individual stages of PLC testing. In ICSs, evaluations that stop at software exploitation, an accepted write, or tool access may therefore mischaracterize physical risk. We present PLCBENCH, to our knowledge, the first real-PLC hardware-in-the-loop (HIL) framework for characterizing this cyber-to-physical capability and its boundaries. It combines vendor-native interaction, commercial PLC execution, closed-loop reduced-order process simulation, and independent outcome verification. A deterministic evaluator applies fixed rules to runner, communication, PLC-object, and process records to assign six hidden diagnostic flags, distinguishing usable PLC interaction, process-linked manipulation, and sustained physical impact. We instantiate PLCBENCH on four commercial PLCs crossed with four closed-loop workloads. Across five LLM families and 240 real-PLC episodes, 75 episodes (31.3%) sustain their respective physical objectives. Stagewise results show that 98 episodes stop before a valid native read, whereas 62 reach a process-linked write but do not sustain the final objective. Notably, richer process observation is associated with an increase in conditional objective attainment after a process-linked write from 44.2% to 64.0%. These measurements localize failure in configured PLC-process deployments and identify intervention points for future defense evaluation. To support reproducibility, we release the safely disclosable PLCBENCH code and a software-only reproduction pipeline through the accompanying artifact.

5.0Engineering value
7.0Research novelty
4.0Business relevance

Links and sources

Need this topic turned into a technical roadmap?

aipentium can prepare a custom AI literature review, code map, dataset map, and B2B technology assessment.

Request B2B AI research

Comments

No comments yet. Be the first to share your thoughts on this paper.
Login or register to leave a comment