AI paper index

MRI super-resolution in ten sampling steps using a diffusion bridge model

2026-08-09 · arXiv: 2608.08819

One-line summary

An AI research paper on MRI super-resolution in ten sampling steps using a diffusion bridge model.

Engineering notes

Engineering notes will be added by the aipentium editorial team.

Chinese explanation / 中文解读

中文解读待补充:本站会优先为大语言模型、生成式AI、ChatGPT相关技术、计算机视觉、深度学习等高价值论文补充中文说明。

Original abstract

Objective. MRI provides excellent soft-tissue contrast, but long acquisition times can cause patient discomfort and lead to motion artifacts, forcing a trade-off between spatial resolution and scan time. Diffusion-based super-resolution (SR) reconstructs high-resolution (HR) images from low-resolution (LR) inputs, but typically needs many sampling steps and initializes from a Gaussian prior ill-suited to image restoration. We developed an efficient diffusion framework that reconstructs HR MRI directly from LR data. Approach. We propose super-resolution diffusion bridge model (SR-DBM), a super-resolution diffusion bridge model that casts SR as a stochastic transport between the LR and HR image distributions. Through a Doob's h-transform of a mean-reverting stochastic differential equation, SR-DBM pins the process to the paired HR and LR images at its endpoints, initializing reconstruction from the measured anatomy rather than from Gaussian noise. The HR image is recovered by a deterministic reverse trajectory in which a network predicts the clean image at each of only ten sampling steps. We evaluated SR-DBM on ultra-high-field 7T brain T1 MP2RAGE maps and pelvic T2-weighted prostate images against nine comparison methods using PSNR, SSIM, GMSD, and LPIPS. Main results. SR-DBM attained the highest PSNR and SSIM and the lowest GMSD on both datasets (brain: 27.66+-1.52 dB, 0.96+-0.02, 7.96+-1.86$; prostate: 27.87+-2.29 dB, 0.80+-0.05, 8.38+- 1.44), with statistically significant gains over every comparison method (two-sided Wilcoxon signed-rank test with Holm correction, p<0.05). The strongest baseline, SR-EMamba, ranked second. Qualitatively, SR-DBM produced the smallest residual errors and best preserved fine structures and lesions.

5.0Engineering value
7.0Research novelty
4.0Business relevance

Links and sources

Need this topic turned into a technical roadmap?

aipentium can prepare a custom AI literature review, code map, dataset map, and B2B technology assessment.

Request B2B AI research

Comments

No comments yet. Be the first to share your thoughts on this paper.
Login or register to leave a comment