AI paper index

DRRG: A Discrete Diffusion Framework for Radiology Report Generation

2026-08-25 · arXiv: 2608.24105

One-line summary

An AI research paper on DRRG: A Discrete Diffusion Framework for Radiology Report Generation.

Engineering notes

Engineering notes will be added by the aipentium editorial team.

Chinese explanation / 中文解读

中文解读待补充:本站会优先为大语言模型、生成式AI、ChatGPT相关技术、计算机视觉、深度学习等高价值论文补充中文说明。

Original abstract

Purpose: Automatic radiology report generation (RRG) has been widely explored to improve reporting accuracy and reduce radiologists' workload. Most existing methods rely on autoregressive (AR) frameworks that generate reports token by token and cannot revise earlier content, making them prone to error propagation and inconsistent with the iterative refinement process of radiological reporting. In contrast, discrete diffusion large language models (DLLMs) generate text through iterative denoising, naturally enabling report refinement. However, DLLMs have not been extensively investigated for RRG. In this study, we developed and evaluated a discrete diffusion framework for RRG that enables iterative refinement rather than conventional left-to-right autoregressive decoding. Materials and methods: We developed DRRG, a DLLM-based framework that formulates RRG as iterative masked-token denoising. DRRG incorporates a clinical-entities-aware complementary mask to improve token supervision coverage and emphasize clinically important entities, together with a concept-conditioning module that injects image-derived clinical concepts into visual representations. DRRG was trained and evaluated on MIMIC-CXR and CheXpert Plus. Results: On MIMIC-CXR, DRRG achieved BLEU-4 of 0.210, CheXpert-F1 of 0.549, RadGraph-F1 of 0.281, GREEN of 0.360, and RaTEScore of 0.604, outperforming the compared methods on most reported metrics, despite employing a substantially smaller LLM decoder. On CheXpert Plus, DRRG achieved the highest BLEU-4 (0.119) and CheXpert-F1 (0.347) among the compared methods. Conclusion: Discrete diffusion provides an effective alternative to autoregressive radiology report generation by enabling iterative, bidirectional report refinement. Incorporating clinically focused masking and image-derived concept conditioning improves report quality and clinical consistency.

5.0Engineering value
7.0Research novelty
4.0Business relevance

Links and sources

Need this topic turned into a technical roadmap?

aipentium can prepare a custom AI literature review, code map, dataset map, and B2B technology assessment.

Request B2B AI research

Comments

No comments yet. Be the first to share your thoughts on this paper.
Login or register to leave a comment